Reported Concern: Freezer compartment formed thick ice in Sector 78 while lower vegetable and bottle rack remained warm.
Technician Inspection: Defrost thermostat was faulty, stopping the defrost heater from melting frost cycle ice.
Repair Work Completed: Replaced the defective sensor, cleared ice using warm steam, and cleared the drain hole.
Parts: ₹450 (Defrost Thermostat)
•
Labour: ₹450 (Defrost System Diagnosis)
•
Total Estimate: ₹900
Airflow opened completely; fresh food section cooled to 4°C within 3 hours.
Reported Concern: Double door refrigerator in Sector 62 made a clicking sound every minute without cooling.
Technician Inspection: Overload protector was tripping due to a faulty starter relay.
Repair Work Completed: Installed a brand-matched starter relay and confirmed normal compressor running current.
Parts: ₹380 (Starter Relay Assembly)
•
Labour: ₹350 (Testing & Installation)
•
Total Estimate: ₹730
Compressor started smoothly and side walls began radiating normal warmth.
Reported Concern: Water pooled beneath the crisper drawer in Sector 137 flat, wetting vegetables.
Technician Inspection: Food particles had blocked the internal drain channel behind the freezer back panel.
Repair Work Completed: Cleared the drain hole with flexible probe wire and flushed with warm water.
Parts: ₹0 (Drain Clearing)
•
Labour: ₹350 (Drain Channel Servicing)
•
Total Estimate: ₹350
Defrost water drained smoothly to the back evaporative tray with zero internal pooling.
Reported Concern: Water droplets formed along inner walls, and milk spoiled quickly in Sector 50.
Technician Inspection: Lower corner of the magnetic door rubber had hardened and warped, leaving an air gap.
Repair Work Completed: Reseated gasket channel using gentle heat and adjusted the door hinge alignment.
Parts: ₹0 (Gasket Reseating)
•
Labour: ₹400 (Hinge Alignment)
•
Total Estimate: ₹400
Door sealed completely airtight with paper grip test passing around all four sides.
Reported Concern: Loud chirping sound came from inside the freezer whenever the door closed in Sector 120.
Technician Inspection: Freezer circulation fan motor bearing had dried out, causing friction noise.
Repair Work Completed: Replaced the 12V circulation fan motor and lubricated airflow flap.
Parts: ₹750 (Circulation Fan Motor)
•
Labour: ₹350 (Freezer Dismantling)
•
Total Estimate: ₹1,100
Fan operated silently with rapid cold air delivery into the lower section.
Reported Concern: Refrigerator display beeped periodically and cooling stayed weak in Sector 93.
Technician Inspection: Temperature sensor probe had drifted out of normal resistance range.
Repair Work Completed: Installed a brand-compatible temperature sensor probe and reset the control board.
Parts: ₹320 (Temperature Sensor)
•
Labour: ₹400 (Sensor Replacement)
•
Total Estimate: ₹720
Freezer temperature dropped to -18°C verified with digital probe.